SanDisk Professional 12TB G-RAID 2, Enterprise-Class 2-Bay Desktop Drive, 7200RPM Ultrastar drive inside, Thunderbolt 3, USB-C, HDMI Port, Hardware RAID

£9.9
FREE Shipping

SanDisk Professional 12TB G-RAID 2, Enterprise-Class 2-Bay Desktop Drive, 7200RPM Ultrastar drive inside, Thunderbolt 3, USB-C, HDMI Port, Hardware RAID

SanDisk Professional 12TB G-RAID 2, Enterprise-Class 2-Bay Desktop Drive, 7200RPM Ultrastar drive inside, Thunderbolt 3, USB-C, HDMI Port, Hardware RAID

RRP: £99
Price: £9.9
£9.9 FREE Shipping

In stock

We accept the following payment methods

Description

Software RAID is a standard feature on almost all dedicated servers. This implies that there is NO charge for using the software RAID 1, which is strongly recommended if you employ localized storage on your machine. It is advised that all disks in RAID arrays have the same category and capacity. Software-based RAID will use a portion of the system’s processing resources to manage the RAID setup. If you intend to optimize the efficiency of a system, such as with RAID 5 or 6 configurations, users should utilize a hardware-first RAID card with ordinary HDDs. 8. Firmware-based RAID The G-RAID Studio is configured as RAID 0 out of the box, but you can switch to RAID 1 or JBOD using the free configuration utility. In RAID 0 on a Mac, formatted with the Mac OS Extended file system, it wrote large files at a rapid 312MB/s and read them at an identical speed. Small files were understandably tougher, but the drive still managed to produce 272MB/s write speeds and 272MB/s read speeds. It also impressed in our new extra-large file transfer test, which uses a mammoth 6GB video file; the G-RAID Studio both wrote and read this file at 323MB/s. RAID is convenient if you are experiencing disk IO difficulties, in which programs wait for the disk to complete tasks. RAID will increase performance by enabling users to access and write information from several drives rather than a single disk. In addition, when you opt for hardware RAID, it will have extra RAM for use as a cache, decreasing the pressure on the physical machine and enhancing overall performance.

RAID 0, sometimes referred to as striped set or striped volume, needs at least two drives. The disks are combined into a single big volume in which data is distributed uniformly throughout the array’s disks. TIMER_END{767,ServletResolution} URI=/content/store/en-ca/products/external-drives/g-technology-g-raid-thunderbolt-3-hdd.html handled by Servlet=Apache Sling Core Default Servlet

With dual Thunderbolt™ 3 ports, you can conveniently daisy chain up to 5 additional devices to stay connected to multiple drives, 4K displays, and more, through a single connection to your computer. High-Speed Data Transfers With Dual Thunderbolt 3 ports, you can conveniently daisy chain up to 5 additional devices to stay connected to multiple drives, 4K displays, and more, through a single connection to your computer. High-Speed Data Transfers The requested URL /content/store/en-ca/products/external-drives/g-technology-g-raid-thunderbolt-3-hdd.html resulted in an error in Apache Sling Core Default Servlet. Request Progress: The IT infrastructure administrator may easily replace or add disks to the relevant RAID Group if a drive crashes or new drives are required. Afterward, they can dynamically redistribute the data among the pool’s current drives. Only a couple of PC motherboards support Thunderbolt 2, but PCI-Express add-in cards can upgrade existing systems. Whether you go down this route or plug the G-RAID Studio into a Mac, it will produce blisteringly fast transfer speeds.

The requested URL /content/store/en-gb/brand/sandisk-professional/g-raid-shuttle.html resulted in an error in Apache Sling Core Default Servlet. Request Progress: See More: What Is Enterprise Data Management (EDM)? Definition, Importance, and Best Practices What Are The Types of RAID Storage? Varying levels have their own types of redundancy; therefore, depending on the application, a compromise involving fault tolerance and speed is often necessary. RAID 0, RAID 1, RAID 5, RAID 6, and RAID 10 are the primary RAID levels (there are others like RAID 3, which is not so frequently used). Let’s first explore these five RAID types: 1. RAID 0 RAID Groups combine a collection of disks, often two or more similar units, into a single logical unit. If disks of varied sizes are connected to a common RAID Group, all disks in that group will work per the disk size with the least capacity. Likewise, if a RAID Group has many types of drives (SSD, HHD, SAS), the group will operate based on the weakest disk. Even though RAID Groups significantly improve the storage’s availability and performance, it is essential to build them depending on each group’s capacity and disk type. This technique is often referred to as “hardware-assisted software RAID” or “hybrid model RAID” since it requires little hardware assistance. This architecture has a benefit over traditional software RAID in that, in a redundancy state, the boot disk is protected against malfunctions (due to the firmware) while booting.Switching to RAID 1, where files are mirrored across the two disks, transfer speeds were understandably slower, but the G-RAID Studio still produced some impressive numbers. Large files were written at 156MB/s and read at 147MB/s, small files were written and read at 153MB/s, and the extra-large files was written at 161MB/s and read at 147MB/s. TIMER_END{759,resolveServlet(/content/store/en-ca/products/external-drives/g-technology-g-raid-thunderbolt-3-hdd)} Using servlet Apache Sling Core Default Servlet Therefore, the RAID Groups are integrated to form storage pools for improved performance and simplicity of administration. This enables enterprises to comfortably scale to meet their demands by installing disks or RAID Groups while increasing LUN storage space. Typical RAID setups are referred to as levels. There were initially five of these, but there are now many more, including many nested and several non-standard (often proprietary) levels.

Cannot find servlet to handle resource /content/store/en-ca/products/external-drives/g-technology-g-raid-thunderbolt-3-hdd Cannot find servlet to handle resource /content/store/en-ca/products/external-drives/g-technology-g-raid-thunderbolt-3-hdd (500) TIMER_END{597,resolveServlet(/content/store/en-gb/brand/sandisk-professional/g-raid-shuttle)} Using servlet Apache Sling Core Default Servlet For maximum performance, G-RAID 2 comes ready to go in RAID 0 and can be configured to RAID 1 (mirroring) or JBOD for ultimate flexibility. Cannot find servlet to handle resource /content/store/en-gb/brand/sandisk-professional/g-raid-shuttle Cannot find servlet to handle resource /content/store/en-gb/brand/sandisk-professional/g-raid-shuttle (500)This is the lowest rate of RAID redundancy and is also known as mirroring since identical data is duplicated across two drives. It supports around twice the read efficiency of one drive but no enhancement in writing throughput. Data is always available as long as at least one disk is operational. 3. RAID 5 For information on changing RAID settings, please refer to Answer ID 30547: Configure G-RAID SHUTTLE Disk Array (RAID). As previously stated, mirroring is the duplication of data over several disks, striping is the distribution of data across multiple disks, and error correction is the storage of redundant data to enable the detection and possible repair of errors (also called fault tolerance). Depending on the system’s needs, one may use any or all of these approaches in various RAID configurations.

With a premium, anodized aluminium enclosure, the G-RAID™ 2 pairs beautifully with your high-end computer and gives you durable strength you can feel. Built-in Hardware RAID A minimum of two RAID 1 sets are nested inside a RAID 0 setup in RAID 10. This combines performance with perhaps increased fault tolerance. Mirroring provides extra redundancy, allowing you to maintain the material regardless of whether you lose 50% of your disks – assuming your mirrored copy is not corrupted. When reliability and stability are crucial for intensive processes, corporations and other pro-units employ RAID 10. For all your demanding workloads and mission-critical content, you can rely on the power and enhanced reliability of the enterprise-class 7200RPM Ultrastar® hard drives inside. Daisy-chaining for up to 5 Additional DevicesRAID storage can be handy for companies looking to scale their on-premise data infrastructure. Balancing your investments in cloud and disk-based storage systems is essential in an increasingly hybrid computing world. They provide the perfect mix of hardware and virtualization so that you can scale freely without compromising on control. See More: What Is a Data Catalog? Definition, Examples, and Best Practices How did RAID storage come into being? For maximum performance, the SanDisk Professional G-RAID Shuttle SSD device comes in RAID 5 out of the box and supports RAID 0, 1, 5, 10 and 50 to provide a versatile and flexible storage solution. The reason? It all boils down to the two hard drives inside the G RAID, which are spinning at 7,200rpm. This means that much of Thunderbolt's vaunted 10Gb/s bandwidth is all but redundant when running a single device.



  • Fruugo ID: 258392218-563234582
  • EAN: 764486781913
  • Sold by: Fruugo

Delivery & Returns

Fruugo

Address: UK
All products: Visit Fruugo Shop